A semiconductor OEM sends your CNC shop an RFQ for a vacuum chamber. The drawing says “leak rate < 1×10¹&sup9; mbar·L/s”. Your shop has never seen this requirement before. What does it mean? Can your machining actually achieve it? And how do you write vacuum leak specifications into RFQs so that both sides agree on what “pass” looks like? This page answers all three.
Leak rate is not pressure. It is a flow rate — the volume of gas (in mbar·L, which is equivalent to Pa·m³) that enters or leaves the chamber per second. A leak rate of 1×10¹&sup9; mbar·L/s means: if you sealed the chamber and waited, gas would seep in at a rate equivalent to 0.000000001 mbar·L every second.
To put this in perspective: a single through-hole of 0.1 mm diameter at atmospheric pressure differential produces a leak rate of roughly 1×10¹&sup4; mbar·L/s — 10,000 times the spec. The chamber effectively cannot have any through-path from outside to inside, not even a microscopic porosity path in a weld or a sub-surface crack in a casting.
| Leak Rate (mbar·L/s) | Equivalent Hole Size (approx.) | Typical Application |
|---|---|---|
| 1×10¹³ | ~1 mm through-hole | Rough vacuum systems (vacuum packaging, suction cups) |
| 1×10¹&sup5; | ~0.1 mm through-hole | Industrial vacuum (furnaces, coating chambers) |
| 1×10¹&sup7; | Micro-porosity in weld | High vacuum (SEM chambers, sputtering systems) |
| 1×10¹&sup9; | Sub-nanometer pathway | Semiconductor process chambers (CVD, PVD, etch) |
| 1×10¹¹ | Crystal lattice diffusion level | Ultra-high vacuum (MBE, ion implant, EUV optics) |
Vacuum technology classifies systems into three main ranges. Each range has different leak rate expectations, different machining requirements, and different test methods:
| Vacuum Range | Pressure Range | Required Leak Rate | Typical Sealing | CNC Relevance |
|---|---|---|---|---|
| Rough vacuum | 1000 to 1 mbar | < 1×10¹&sup5; mbar·L/s | O-rings (NBR, Viton) | Standard machining; surface finish Ra 1.6–3.2 μm on seal faces |
| High vacuum (HV) | 10¹³ to 10¹&sup9; mbar | < 1×10¹&sup9; mbar·L/s | Metal gaskets (Cu, Al) or knife-edge seals | Precision machining; seal face Ra < 0.8 μm; flatness < 0.01 mm |
| Ultra-high vacuum (UHV) | < 10¹&sup9; mbar | < 1×10¹¹ mbar·L/s | ConFlat (knife-edge Cu gaskets), welded joints | Ultra-precision; Ra < 0.4 μm; no subsurface porosity; outgassing-controlled materials |
Key insight for CNC shops: The leap from rough vacuum to high vacuum is primarily a sealing surface quality problem. A chamber that holds 1×10¹&sup5; with an O-ring might leak at 1×10¹&sup7; if the O-ring groove has a tool mark deeper than 5 μm. For high vacuum and UHV, the sealing surface must be machined to a mirror finish with no visible tool marks, and the entire chamber must be free of subsurface porosity (which rules out cast chambers without impregnation).
The only practical method for measuring leak rates below 1×10¹&sup7; mbar·L/s is helium mass spectrometry (He-MS). Here is how it works:
| He-MS Parameter | Typical Value | Notes |
|---|---|---|
| Minimum detectable leak rate (vacuum mode) | 5×10¹¹³ Pa·m³/s (5×10¹¹³ mbar·L/s) | State-of-the-art instruments (Pfeiffer ASM 340) |
| Minimum detectable leak rate (sniffer mode) | 1×10¹&sup7; Pa·m³/s | Less sensitive; used for locating large leaks |
| Test gas | Helium 4.6 (99.996% purity) | Higher purity reduces background noise |
| Response time | < 1 second | Modern instruments |
| Typical test time per chamber | 30–60 minutes | Includes pump-down + full spray survey |
Most RFQs get the leak rate specification wrong. Here is what a complete vacuum specification looks like:
Common RFQ mistakes to avoid:
Achieving a leak rate of 1×10¹&sup9; mbar·L/s is not just about the seal — the chamber body itself must be leak-tight. Here are the machining requirements:
| Feature | Requirement for HV (<10⁻⁸) | Requirement for UHV (<10⁻⁷) |
|---|---|---|
| Seal face surface finish | Ra < 0.8 μm | Ra < 0.4 μm |
| Seal face flatness | < 0.02 mm | < 0.005 mm |
| O-ring groove finish | Ra < 1.6 μm | Not used (metal seals only) |
| Knife-edge seal geometry | N/A | Edge angle 60–90°; edge radius < 5 μm |
| Wall porosity (castings) | Must be impregnated or use wrought stock | Wrought stock only; no castings |
| Weld quality | Full penetration, no porosity; X-ray or dye-pen inspected | Same + vacuum-fired; outgassing-controlled per ASTM F595 |
| Material outgassing | Not typically specified | Outgassing rate < 1×10¹¹&sup0; mbar·L/s·cm² |
When a chamber fails the He-MS leak test (measured leak rate exceeds spec), follow this workflow:
| Stage | Check | Why |
|---|---|---|
| Drawing | Leak rate specified numerically with test method | “Vacuum tight” is not a spec |
| Drawing | Seal face finish and flatness toleranced | Untoleranced seal faces are the #1 leak source |
| Material selection | Wrought stock specified for HV/UHV (no castings) | Casting porosity is a hidden leak path |
| Machining | Seal faces machined in final setup (no re-fixture) | Re-fixturing breaks flatness |
| Machining | Knife-edge geometry verified (angle, edge radius) | Damaged knife-edge = failed metal seal |
| Assembly | Gaskets new, clean, correctly torqued | Reused Cu gaskets leak at HV |
| Pre-test | All surfaces cleaned per ASTM F595 (solvent clean, bake if UHV) | Contamination on seal face = leak path |
| Test | He-MS detector calibration current; background < 10% of spec | Uncalibrated detector = invalid result |
It means gas enters (or leaves) the chamber at a rate of 0.000000001 mbar·L per second. In practical terms, this is equivalent to saying the chamber has no through-path larger than a sub-nanometer channel — effectively, the entire chamber body and all seals must be impermeable to gas at the molecular level. This is the standard requirement for semiconductor process chambers (CVD, PVD, etch tools).
Yes, if the shop has precision machining capability and follows vacuum-grade practices. The key requirements are: (1) seal face surface finish Ra < 0.8 μm for high vacuum, Ra < 0.4 μm for UHV; (2) seal face flatness < 0.01 mm; (3) wrought material stock (no casting porosity); (4) welds that are full-penetration and inspected. 5-axis machining helps by completing all seal features in one setup. The shop does not need to own a He-MS detector — leak testing can be outsourced to a vacuum lab.
Vacuum mode evacuates the chamber and sprays helium on the outside — it measures the total leak rate but cannot locate individual leaks. Sensitivity: down to 5×10¹¹³ mbar·L/s. Sniffer mode pressurizes the chamber with helium and probes the outside — it can locate individual leaks but is less sensitive (down to ~1×10¹&sup7; mbar·L/s). For semiconductor RFQ acceptance, vacuum mode is the standard. Sniffer mode is used during troubleshooting to find leak positions.
Seal face machining quality. Tool marks deeper than a few micrometers on a knife-edge or ConFlat flange face create a leak path that no gasket can seal. The second most common cause is casting porosity in chamber bodies — subsurface gas pockets that create micro-channels from inside to outside. For high vacuum and UHV, wrought stock (forged or bar) should always be specified instead of castings.
Include a note with four elements: (1) numeric leak rate (e.g., < 1×10¹&sup9; mbar·L/s); (2) test method (He-MS, vacuum mode); (3) test conditions (base pressure before test, gasket type, torque values); (4) documentation required (test report with equipment calibration date, background reading, and measured leak rate). Never write “vacuum tight” without a number — it is unenforceable.
No. Many precision CNC shops outsource He-MS leak testing to specialized vacuum labs or testing services. The critical capability is the machining quality that allows the chamber to pass the test. If you can machine seal faces to Ra < 0.4 μm with flatness < 0.005 mm, and use wrought stock with inspected welds, the chamber will pass — regardless of who performs the leak test. Partner with a local vacuum lab for acceptance testing.
Most semiconductor process chambers operate in the high vacuum range (10¹³ to 10¹&sup9; mbar), with leak rate requirements of < 1×10¹&sup9; mbar·L/s. Ultra-high vacuum processes (MBE, ion implant, EUV) operate below 10¹&sup9; mbar and require leak rates < 1×10¹¹ mbar·L/s. The machining requirements for UHV are significantly more stringent: Ra < 0.4 μm, flatness < 0.005 mm, metal seals only, and outgassing-controlled materials.
We machine vacuum chambers from wrought aluminum, 316L stainless, and titanium to high-vacuum specifications. Seal faces to Ra < 0.4 μm, flatness < 0.005 mm, 5-axis capability for complex multi-port designs. Leak testing available through our partner vacuum labs.
Request a Quote